Well Pumps & Pressure
Pump sizing, pressure tanks and drawdown.
5 articles
What size pressure tank for a 12 GPM pump at 40/60 psi?
12 GPM pump at 40/60 psi
62 gal tank
16.1 gal of drawdown — 1.3 minutes of run time per cycle
| Tank sizenominal size on the label | 62gal |
|---|---|
| Usable drawdown26% of the tank at 40/60 psi — the rest is air | 16.1gal |
| Drawdown needed12 GPM × 1 minute minimum run | 12gal |
| Run time per cycleunder one minute and the motor never sheds its start heat | 1.3min |
| One size down (44 gal)below the one-minute rule — this is the size that kills pumps | 1min |
| Pre-charge pressure2 psi below cut-in, measured with the tank empty and the pump off | 38psi |
Notes
- A 62 gallon tank does not hold 62 gallons of water. Most of it is compressed air. At 40/60 psi you get 16.1 gallons of usable drawdown, and that is the only number that matters when sizing.
- Higher pressure gives you LESS drawdown, not more. 40/60 psi yields 26% of the tank against 31% at 30/50. Turning the pressure switch up for better showers shrinks the water buffer and makes the pump start more often — the opposite of what most people expect when they make that change.
- The one-minute rule is about the motor, not the water. A submersible pump has to run at least a minute per start to shed the heat of starting. Pumps die from cycle count, not run hours. A 44 gallon tank here gives only 1 minutes — that is the choice that quietly destroys pumps, and it saves about a hundred dollars once.
- Set the pre-charge to 38 psi, with the tank empty. Two psi below cut-in, measured at the schrader valve with the pump off and a tap open. Wrong pre-charge is the most common failure in a well system: too high and the tank waterlogs, too low and drawdown collapses. Check it yearly — it is a five-minute job with a tyre gauge.
- Constant-pressure (variable speed) pumps change this arithmetic completely: they modulate instead of cycling, so they need only a small tank. If the system has one, size by the manufacturer's table rather than by the rule above.
Well pressure tank size
24 calculations · browse all
- What size pressure tank for a 5 GPM pump at 30/50 psi?
- What size pressure tank for a 5 GPM pump at 40/60 psi?
- What size pressure tank for a 5 GPM pump at 50/70 psi?
- What size pressure tank for a 7 GPM pump at 30/50 psi?
- What size pressure tank for a 7 GPM pump at 40/60 psi?
- What size pressure tank for a 7 GPM pump at 50/70 psi?
- What size pressure tank for a 10 GPM pump at 30/50 psi?
- What size pressure tank for a 10 GPM pump at 40/60 psi?
- What size pressure tank for a 10 GPM pump at 50/70 psi?
- What size pressure tank for a 12 GPM pump at 30/50 psi?
- What size pressure tank for a 12 GPM pump at 40/60 psi?
- What size pressure tank for a 12 GPM pump at 50/70 psi?
- What size pressure tank for a 15 GPM pump at 30/50 psi?
- What size pressure tank for a 15 GPM pump at 40/60 psi?
- What size pressure tank for a 15 GPM pump at 50/70 psi?
- What size pressure tank for a 20 GPM pump at 30/50 psi?
- What size pressure tank for a 20 GPM pump at 40/60 psi?
- What size pressure tank for a 20 GPM pump at 50/70 psi?
- What size pressure tank for a 25 GPM pump at 30/50 psi?
- What size pressure tank for a 25 GPM pump at 40/60 psi?
- What size pressure tank for a 25 GPM pump at 50/70 psi?
- What size pressure tank for a 30 GPM pump at 30/50 psi?
- What size pressure tank for a 30 GPM pump at 40/60 psi?
- What size pressure tank for a 30 GPM pump at 50/70 psi?
The Pressure Tank — Precharge, Cut-In and Why Pumps Short CycleThe pump does not run continuously, and the reason it does not is a cushion of air in a tank.
Submersible or Jet — Which Pump a Well Has and WhyAtmospheric pressure will lift water about twenty-five feet and no further, which is the whole reason deep wells use a different pump.
Well Yield — How Much Water the Well Can Actually GiveA bigger pump does not make a well produce more water. It makes it run dry faster.
Low Water Pressure on a Well — Working Through the CausesLow pressure everywhere and low pressure at one tap are different problems, and that is the first thing to establish.
Well Pump Short Cycling — It Is Almost Always the TankMotors are killed by starting, not by running. A short-cycling pump can burn out in months, and the cause is usually a tank that costs a fraction of the pump.